Model FP-100
FP-100 Instruction Manual Rev. 0.0 Page 27 of 30
8. Appendix
8.1 Specifications
System Specifications
Sensor Type: Continuous diffusion/adsorption type
Matched-Pair Catalytic Bead type
Plug-in Replaceable Type
Sensor Life: 3-5 years typical
Measuring Ranges: 0-100% LEL
Accuracy/ Repeatability: ± 3% LEL in 0-50% LEL range, ± 5% LEL in 51-100% LEL range
Response Time: T50 < 10 seconds, T90 < 30 seconds
Electrical Classification: CSA and US (NRTL)
Class I, Division 1, Groups A, B, C, D
ATEX
Class I, Zone 1, Group IIB+H
2
Ex d IIB+H
2
, T4
Approvals:
C
CSA
US
, ATEX, CE Marking
Warranty: Electronics – 2 years
Plug in Sensor – 2 years
Environmental Specifications
Operating Temperature: -40°C to +75°C typical
Storage Temperature: -35°C to +55°C typical
Operating Humidity: 0-100% RH non-condensing
Operating Pressure: Ambient ± 10%
Electrical Specifications
Input Voltage: 10-28 VDC
Power Consumption: Normal operation = 37 mA (0.89 watts @ 24VDC);
Maximum = 56 mA (1.35 watts @ 24VDC)
RFI/EMI Protection: Complies with EN61326
Analog Output: Linear 4-20mA DC current
750 ohms maximum loop load @ 24VDC
0 mA All Fault Diagnostics
4-20 mA 0-100% full-scale
22 mA Over-range condition